Send Message
Home ProductsTensile Strength Testing Machine

IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine

IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine

  • IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
  • IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
  • IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
  • IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine
Product Details:
Place of Origin: China
Brand Name: HongCe
Certification: TUV、ITS、CSA、BV、SGS 、CNAS(cost additional)
Model Number: LTI-1
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiatable
Packaging Details: Plywood
Delivery Time: 25 days
Payment Terms: T/T
Supply Ability: 15 set per month
Contact Now
Detailed Product Description
Station: Single Station/Three Stations Weight Of The Impact Hammer (g): 1000±2 And 100±1
Height Of The Impact (mm): 100 Standard: IEC60884-1 24.4 Figure 27 IEC60884-1 30.4 Figure 42
High Light:

tensile strength testing equipment

,

tensile testing equipment

IEC 60884-1 2013 Clause 24.4 Low Temperature Tensile Strength Testing Machine

 

 

Product information:
The HT Apparatus for impact test at low temperature confirms to the standard of IEC60884 figure 27 and figure 42. The first one is fit for impact test of wire while the latter one is applied for the impact test of plug, socket, switch, wire and electrical conduit.

Standard: IEC 60884-1 2013 clause 24.4, 30.4, figure 27 and 42, IEC60811-1-4, VDE0620 and so on

Application: This device is use for checking the impact resistance at low temperature of electrical accessories, as well as wires and cables.

Test sample: Electrical accessories, surface type mounting boxes, screw glands, covers, wires and cables etc.

Feature: This device should be used with low temperature chamber, the device should be placed on the sponge rubber pad of about 40mm thick, and should be put in the low temperature chamber before and during the test.

 

Technical parameters:

Model Impact test apparatus H926 Impact test apparatus H926A
Station Single station Three stations
Weight of the impact hammer (g) 1000±2 and 100±1 100, 200, 300, 400, 500, 600, 750, 1000, 1250, 1500(See table 1 and 2)
Height of the impact (mm) 100 100
Steel intermediate piece Φ20, bottom end rounded R300, 100g Φ20, bottom end rounded R300, 100g
Standard

IEC60884-1 24.4 Figure 27

IEC60884-1 30.4 Figure 42

IEC60811-1-4
Operation Manual, mechanical release Manual, mechanical release

 

Table1 For power cables for fixed installation, the mass of the hammer for testing the samples shall be as given in the following table:

Overall diameter (mm) Mass of hammer (g)
Above Up to and including
- 4.0 100
4.0 6.0 200
6.0 9.0 300
9.0 12.5 400
12.5 20.0 500
20.0 30.0 750
30.0 50.0 1000
50.0 75.0 1250
75.0 - 1500

Table 2 For flexible cables and cords and telecommunication cables, the mass of the hammer for testing the sample shall be as follows:

Overall diameter (mm) Mass of hammer (g)
Above Up to and including
For flat cords 100
- 6.0 100
6.0 10.0 200
10.0 15.0 300
15.0 25.0 400
25.0 35.0 500
35.0 - 600

 